1 ton capacity steam boiler

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :1 ton capacity steam boiler
  • Supply Capacity : 10 units/month :1 ton capacity steam boiler
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • HS26-060-1P GCS16-090-350-2Y - Lennox

    HS26 is the Series, 060 is the Capacity, 1P (1) is the Dash Number and (P) is the Power Characteristics. -14 = 1 ton -95 = 7½ tons -21 = 1½ tons -135 = 10 tons GWB Gas fired hot water boiler GSB Gas fired steam boilerGet Price

  • Power plant and calculations: Boiler calculations for

    Feb 12, 2021 · 20-Calculate the specific fuel consumption of a power plant. If steam Turbine consumes 4.2 Tons of steam to generate 1 MW of power. Assume steam to fuel ratio of Boiler is 4.8. We have Specific fuel consumption (SFC) = Specific steam consumption (SSC) / Steam to fuel ratio of Boiler (SFR) SFC = 4.2 / 4.8 =0.875 kg of fuel for generating 1 kw of Get Price

  • How much coal is required to generate 1 MWH of electricity?

    Mar 09, 2017 · During installation of industrial steam boiler, 1-2 experienced engineering and technical personnel will be sent for the site representative for technical tests and installation instructions free of charge; processing the various problems arising in the course timely while installing. 1 ton steam boiler. 2 ton steam boiler. 3 ton steam Get Price

  • How much coal is required to generate 1 MWH of electricity?

    Mar 09, 2017 · During installation of industrial steam boiler, 1-2 experienced engineering and technical personnel will be sent for the site representative for technical tests and installation instructions free of charge; processing the various problems arising in the course timely while installing. 1 ton steam boiler. 2 ton steam boiler. 3 ton steam Get Price

  • Unit Conversion--How to Calculate Boiler Horsepower

    1 Ton Gas Steam Boiler in Chile Application: Rubber Vulcanization Capacity: 1 Ton/hr Checking Order Quality Test Before Delivery Check Items When Packing Packaging And Transport. Get An Instant Quotation Consult online customer service. For all inquiries, please fill in the form below (* are required) to send us a brief message, and we will get Get Price

  • Steam Boiler: Working principle and Types of Boiler

    Feb 24, 2012 · As the water and steam both are in same vessel a fire tube boiler cannot produce steam at very high pressure.. Generally it can produce maximum 17.5 kg/cm 2 and with a capacity of 9 Metric Ton of steam per hour.. Types of Fire Tube Boiler. There are different types of fire tube boiler likewise, external furnace and internal furnace fire tube boiler.Get Price

  • Amazon.com: Breville BES920XL Dual Boiler Espresso Machine

    the Dual Boiler Espresso Machine by Breville, BES920XL Commercial features and performance, in a domestic foot print. At the heart of this machine is it's dual boiler heating system. The boiler, for the espresso shot, is PID temperature controlled, while a separate steam boiler offers instant and powerful steam on demand.Get Price

  • Mini Steam Powered Generating Sets | Claverton Group

    Jan 27, 2010 · Steam power plant consisting of (1) Single cylinder double acting steam engine 5 hp, cylinder dia 3″xstroke 4″, complete with reverse mechanism, hand lubricating pump for cylinder lubrication, drip lubricator for crosshead lubrication and 12″ pulley (2) Water tube Yarrow type boiler suitable for biomass firing with 54 sq ft heating Get Price

  • Steam locomotive - Wikipedia

    A steam locomotive is a rail vehicle that provides the force to move itself and other vehicles by means of the expansion of steam.: 80 It is fuelled by burning combustible material (usually coal, oil or, rarely, wood) to heat water in the locomotive's boiler to the point when it becomes gaseous and its volume increases 1,700 times. Functionally, it is a steam engine on wheels.Get Price

  • The Kraft Recovery Process - TAPPI

    The amount of steam produced is typically about 3.5 kg per kg black liquor solids, but can range from 2.5 to about 3.8 kg steam per kg black liquor solids, depending on the thermal efficiency of the recovery boiler. The high pressure steam is passed through a steam turbine to generate electricity. Depending on the quality of theGet Price

  • Sterlco | Sterling Steam Control Part Numbers

    4100 SERIES SIMPLEX, 15 GAL, 1: GPAC 40: 460/3/60 Chiller 10 Ton Air: 41340-JDAX-1: Condensate Return System: GPAC-20-1: GP Portable Chiller 460V/3/60: 4134-JDFX: 4100 Ser Boiler w/ Motor Start: GPACLiming: GP PortableChiller 230V/3/60HZ: 4136-JD: STERLCO CONDNSATE PUMP ASSEMB. GPAC30: 7 TON AIR COOLED PKGD CHILLER: 4136JDFAX: …Get Price

  • High-Performance HVAC | WBDG - Whole Building Design Guide

    Nov 07, 2016 · Variable capacity boiler plants (e.g., step-fired (hi/lo) boilers, modular boiler plants, modulating flame boilers); Scroll compressors are manufactured in the 1 to 15 ton range. Multiple compressors can be found in water chillers with capacities of 20 to 500 tons. gas or fuel oil, or indirect-fired. Indirect-fired units may use Get Price

  • NSW Preserved Steam Locomotives

    1067is a luffing crane tank locomotive with max. 7 ton crane capacity. 1067 was acquired by the DSR&M in a dismantled state after the NSWGR had dismantled the locomotive for an overhaul which subsequently did not proceed. It retains its saturated steam boiler as …Get Price

  • Titanic's Propulsion Plant

    Therefore, in terms of boiler supply, we get 12,525/2.0 = 6,262 lbs/minute, or expressed in tons (2240 lbs/long-ton) per minute, we get 6,262/2240 = 2.8 tons of steam per minute being supplied from the 24 double-ended boilers. This is a supply rate of 6,262/24 = 260.9 lbs of steam per minute per boiler.Get Price

  • 10.2 Chemical Wood Pulping - US EPA

    1.0 kilograms per air-dried megagram (kg/Mg) (1 to 2 pounds per air-dried ton [lb/ton]) of pulp produced from the lime kiln and recovery furnace, respectively.5-6 A major source of emissions in a kraft mill is the boiler for generating auxiliary steam and power. The fuels are coal, oil, natural gas, or bark/wood waste.Get Price

  • Pere Marquette 1225 :: Steam Railroading Institute

    Water Capacity: 22,000 Gallons. Coal Capacity: 22 Tons. Water Consumption: 150 Gal/Mile. Coal Consumption: 1 Ton/12 Miles. Fuel: Soft Coal (1 Ton= $200) Tractive Force: 69,350 lbs. Tractive Horsepower: 5,000 hp. Cylinder Horsepower: 2,979 hp. Driving Wheel Diameter: 69 Inches. Boiler Pressure: 245 psi (8 hrs to fill boiler with steam) Grate Get Price

  • Steam locomotive - Wikipedia

    A steam locomotive is a rail vehicle that provides the force to move itself and other vehicles by means of the expansion of steam.: 80 It is fuelled by burning combustible material (usually coal, oil or, rarely, wood) to heat water in the locomotive's boiler to the point when it becomes gaseous and its volume increases 1,700 times. Functionally, it is a steam engine on wheels.Get Price

  • Power plant and calculations: Boiler calculations for

    Feb 12, 2021 · 20-Calculate the specific fuel consumption of a power plant. If steam Turbine consumes 4.2 Tons of steam to generate 1 MW of power. Assume steam to fuel ratio of Boiler is 4.8. We have Specific fuel consumption (SFC) = Specific steam consumption (SSC) / Steam to fuel ratio of Boiler (SFR) SFC = 4.2 / 4.8 =0.875 kg of fuel for generating 1 kw of Get Price

  • (PPT) PIPE 1 COACHING NOTES 150 | pauline agustin

    The unit has an EER of 11.1. Determine the maximum cooling capacity of the unit in tons of refrigeration. v2 = 0.06081 m3/kg A. 0.821 B. 1.261 C. 0.344 D. 1.609 60. Steam leaves an industrial boiler at 827.4 kPa and 171.6oC. A portion of the steam is passed through a throttling calorimeter and is exhausted to the atmosphere when the Get Price

  • POSITIONS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

    BS1 A Standing Pilot Natural Draft Steam Boiler BS2 A IID Natural Draft Steam Boiler 80% Fixed Capacity 018 1.5 ton 024 2 ton 030 2.5 ton Etc. MODEL CODE SIZE 001 First Size 002 Second Size 003 Third Size 004 Fourth Size UNIT OF EXAMPLE CAPACITY RECORD OF CODEGet Price

  • Mini Steam Powered Generating Sets | Claverton Group

    Jan 27, 2010 · Steam power plant consisting of (1) Single cylinder double acting steam engine 5 hp, cylinder dia 3″xstroke 4″, complete with reverse mechanism, hand lubricating pump for cylinder lubrication, drip lubricator for crosshead lubrication and 12″ pulley (2) Water tube Yarrow type boiler suitable for biomass firing with 54 sq ft heating Get Price

  • POSITIONS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

    BS1 A Standing Pilot Natural Draft Steam Boiler BS2 A IID Natural Draft Steam Boiler 80% Fixed Capacity 018 1.5 ton 024 2 ton 030 2.5 ton Etc. MODEL CODE SIZE 001 First Size 002 Second Size 003 Third Size 004 Fourth Size UNIT OF EXAMPLE CAPACITY RECORD OF CODEGet Price

  • Steam Boiler: Working principle and Types of Boiler

    Feb 24, 2012 · As the water and steam both are in same vessel a fire tube boiler cannot produce steam at very high pressure.. Generally it can produce maximum 17.5 kg/cm 2 and with a capacity of 9 Metric Ton of steam per hour.. Types of Fire Tube Boiler. There are different types of fire tube boiler likewise, external furnace and internal furnace fire tube boiler.Get Price

  • Pipe Sizing Steam Supply andCondensateReturn Lines

    NOTE: The velocity ranges shown in Steam Pipe Capacity Tables 45-1 through 46-4 can be used as a general guide in sizing steam piping. All the steam flows above a given colored line are less than the velocities shown in the tables. Pipe Sizing Two principal factors determine pipe sizing in a steam system: 1. The initial pressure at the boiler andGet Price

  • (PDF) Report on "Steam Power Plant" | Saddam Hussain Sohag

    Steam condensing system consists of the following: (a) Condenser (b) Cooling water (c) Cooling tower (d) Hot well (e) Condenser cooling water pump (f) Condensate air extraction pump (g) Air extraction pump (h) Boiler feed pump (i) Make up water pump. 3.1.2 Steam production: Boiler is an apparatus to produce steam.Get Price

  • (PDF) Report on "Steam Power Plant" | Saddam Hussain Sohag

    Steam condensing system consists of the following: (a) Condenser (b) Cooling water (c) Cooling tower (d) Hot well (e) Condenser cooling water pump (f) Condensate air extraction pump (g) Air extraction pump (h) Boiler feed pump (i) Make up water pump. 3.1.2 Steam production: Boiler is an apparatus to produce steam.Get Price

  • Pipe Sizing Steam Supply andCondensateReturn Lines

    NOTE: The velocity ranges shown in Steam Pipe Capacity Tables 45-1 through 46-4 can be used as a general guide in sizing steam piping. All the steam flows above a given colored line are less than the velocities shown in the tables. Pipe Sizing Two principal factors determine pipe sizing in a steam system: 1. The initial pressure at the boiler andGet Price

  • Sterlco | Sterling Steam Control Part Numbers

    4100 SERIES SIMPLEX, 15 GAL, 1: GPAC 40: 460/3/60 Chiller 10 Ton Air: 41340-JDAX-1: Condensate Return System: GPAC-20-1: GP Portable Chiller 460V/3/60: 4134-JDFX: 4100 Ser Boiler w/ Motor Start: GPACLiming: GP PortableChiller 230V/3/60HZ: 4136-JD: STERLCO CONDNSATE PUMP ASSEMB. GPAC30: 7 TON AIR COOLED PKGD CHILLER: 4136JDFAX: …Get Price

  • Unit Conversion--How to Calculate Boiler Horsepower

    1 Ton Gas Steam Boiler in Chile Application: Rubber Vulcanization Capacity: 1 Ton/hr Checking Order Quality Test Before Delivery Check Items When Packing Packaging And Transport. Get An Instant Quotation Consult online customer service. For all inquiries, please fill in the form below (* are required) to send us a brief message, and we will get Get Price

  • Air Pollution Control Technology Fact Sheet

    boiler operating at 85% capacity requires approximately 17 m 3 ( 600 ft 3). For the same sized coal-fired boiler, the required catalyst is on the order of 42 m3 (1,500 ft3). (NESCAUM 2000). SCR is a proprietary technology and designs on large combustion units are site specific. Retrofit of SCR on an existing unit can increase costs by over 30% Get Price

Discount
7X24 Online